UK

VENTCROFT

 

DHTML Menu By Milonic JavaScript

   |  Products  |  Fire  |  Fire Performance Cables  | NoBurn Platinum
 

Ventcroft Standard Fire Performance Cables

 




Red, White and Black Standard Fire Cable

  

 

Please click here to
download leaflet

NoBurn Platinum - FAQ's

Now one of the leading brands of fire cable. NoBurn Platinum fire cable is manufactured in the UK using the latest technology, materials and manufacturing equipment. Our materials and production processes are audited by LPCB and BASEC to ensure consistent reliability and quality, with each reel fully traceable by batch number and time and date of manufacture.

NoBurn Platinum is the fastest fire cable to prepare for termination with no troublesome multiple sheaths, foils or wraps to strip. NoBurn Platinum cable has superb working flexibility and stays where you put it, reducing installation time and costs.

Approved by LPCB and BASEC to meet with BS 5839-1:2013 Clause 26.2d Standard, BS EN 50200:2006 + Annex E 30 minutes & BS EN 50200:2006 Class PH30, PH60 & PH120 NoBurn Platinum's core twists will provide the highest level of data protection, ideal for long cable runs and analogue addressable fire systems. Also certified by LPCB and BASEC to BS 7629-1:2008  & BS 6387:1994 Clause 11 CWZ including 3 hour burn test at 950c.

NoBurn Platinum fire cable is also the most highly certified cable for use with Emergency Lighting Systems, certified to exceed BS 5266-1 2011 and BS EN 50200:2006 PH60 - 1 hour duration, NoBurn Platinum is certified by LPCB and BASEC to withstand to PH120 - providing 2 hours of protection. Also suitable for automatic lift doors, air conditioning and computer control where low smoke, fume and zero halogen cable is required.

 

 Features

Fastest Standard Fire Cable to Prepare for Termination
Easy to Install and Superb Working Flexibility
Up to 12 Twists per metre for Data Protection
Red, White, Black & Orange Outer Sheaths Available
1mm,1.5mm, 2.5mm & 4.0mm Conductors
100m, 200m, 500m and Special Lengths Available
Aluminium / Co-polymer Foil Screen
Low Smoke & Zero Halogen
Voltage Rating 300v/500v
Suitable for Zone 1 and Zone 2 hazardous area use
Suitable for Air Conditioning Computer Control & Lift Doors where Low Smoke & Zero Halogen is required
 Approved and Certified to meet

BS 5839-1:2013 Clause 26.2d

'Standard' Fire Cable
BS EN 50200:2006 + Annex E 30 Minutes Fire Resistance Standard
BS EN 50200:2006 PH30, PH60 & PH120 Fire Resistance Standard
BS 7629-1:2008 Fire Resistance Standard
BS 6387:1994 Clause 11 CWZ Fire Resistance Standard
BS EN 50267-2-1:1999 Halogen Emission Standard
BS EN 61034-2:2005 Low Smoke Standard
 Also Approved For
Emergency Lighting Standard BS 5266-1:2011
Voice Alarm Systems Standard BS 5839-8:2013
Voice Communication Standard BS 5839-9:2013
   (Risk Assessment May Demand Mechanical Protection)


 

 Accreditations and third Party Certification



 

LPCB Quality Management
ISO9001:2008 Certification

LPCB Product Certificate 682a


 



 



 

BASEC Quality Management
ISO9001:2008 Certification

BASEC
BS 7629-1:2008 Certificate

BASEC
BS 5839-1:2013 Certificate

 

 Manufacturers Recommended Installation Guide Lines


Recommended metal clip spacing 300mm Horizontal, 400mm Vertical

Recommended Cable Tray Fastening - Metal Tie, spacing every 1.5 metres.

Installation Temperatures:
Minimum installation Temperature
0c
Maximum installation Temperature 70
c

Operating Temperature Temperature:
Minimum -40
c to Maximum +90c

The cable should not be flexed or bent when either the cable or operating temperature is below the recommended installation temperatures.

Minimum Bend Radius = 6 x Diameter
Plastic Clips or ties must not be used as the sole means of support for fire cable.

 

back to top

BS 5839-1:2013

The Standard BS 5839 (fire detection and fire alarm systems for buildings - Code of practice for system design, installation, commissioning and maintenance) relates to the use and standards of Fire Performance Cables.

More Information

back to top

Downloads

The download drop down box allows you to download files for the products on this page. Files include, Instruction Manuals, Sales leaflets, Specifications and Certificates. Adobe Acrobat Reader may be required to read some of the file, a link is included to download the reader if you require it.Get Adobe Reader


 

back to top

NoBurn Platinum Standard Fire Performance Cable

           Red

Red 1.0mm Cores & CPC (earth) Reel Cores Code Pallet Min Qty Trade Per 100m

 

1.0mm 100m 2 Cores & CPC

VFP-210ERH

60 1 TBA
1.0mm 100m 3 Cores & CPC

VFP-310ERH

60 1 TBA
1.0mm 100m 4 Cores & CPC

VFP-410ERH

60 1 TBA
1.0mm 500m 2 Cores & CPC

VFP-210ERH500M

10 1 TBA

 

Red 1.5mm Cores & CPC (earth) Reel Cores

Code

Pallet Min Qty Trade Per 100m
1.5mm 100m 2 Cores & CPC

VFP-215ERH

60 1 TBA
1.5mm 100m 3 Cores & CPC

VFP-315ERH

60 1 TBA
1.5mm 100m 4 Cores & CPC

VFP-415ERH

60 1 TBA
1.5mm 200m 2 Cores & CPC

VFP-215ERH200M

20 1 TBA
1.5mm 200m 4 Cores & CPC

VFP-415ERH200M

20 1 TBA
1.5mm 500m 2 Cores & CPC

VFP-215ERH500M

10 1 TBA
1.5mm 500m 4 Cores & CPC

VFP-415ERH500M

10 1 TBA 

Red 2.5mm Cores & CPC (earth) Reel Cores

Code

Pallet Min Qty  Trade Per 100m
2.5mm 100m 2 Cores & CPC

VFP-225ERH

60 1 TBA
2.5mm 100m 3 Cores & CPC

VFP-325ERH

60 1 TBA
2.5mm 100m 4 Cores & CPC

VFP-425ERH

60 1 TBA
2.5mm 200m 2 Cores & CPC

VFP-225ERH200M

20 1 TBA
2.5mm 500m 2 Cores & CPC

VFP-225ERH500M

10 1  TBA

Red 4mm Cores & CPC (earth) Reel

Cores

Code

Pallet Min Qty Trade Per 100m
4mm 100m 2 Cores & CPC

  VFP-S240ERH

60 1 TBA

back to top

NoBurn Platinum Standard Performance Cable

       White

Red 1mm Cores & CPC (earth) Reel Cores Code Pallet Min Qty Trade Per 100m

 

1.0mm 100m 2 Cores & CPC VFP210EWH 60 1 TBA
1.0mm 100m 3 Cores & CPC VFP-310EWH 60 1 TBA
1.0mm 100m 4 Cores & CPC VFP-410EWH 60 1 TBA
1.0mm 500m 2 Cores & CPC VFP-210EWH500M 10 1 TBA

 

White 1.5mm Cores & CPC
(earth)
Reel Cores Code Pallet Min Qty Trade Per 100m
1.5mm 100m 2 Cores & CPC VFP-215EWH 60 1 TBA
1.5mm 100m 3 Cores & CPC VFP-315EWH 60 1 TBA
1.5mm 100m 4 Cores & CPC VFP-415EWH 60 1 TBA
1.5mm 200m 2 Cores & CPC VFP-215EWH200M 20 1 TBA
1.5mm 200m 4 Cores & CPC VFP-415EWH200M 20 1 TBA
1.5mm 500m 2 Cores & CPC VFP-215EWH500M 10 1 TBA
1.5mm 500m 4 Cores & CPC VFP-415EWH500M 10 1 TBA

White 2.5mm Cores & CPC (earth) Reel Cores Code Pallet Min  Qty  Trade Per 100m
2.5mm 100m 2 Cores & CPC VFP-225EWH 60 1 TBA
2.5mm 100m 3 Cores & CPC VFP-325EWH 60 1 TBA
2.5mm 100m 4 Cores & CPC VFP-425EWH 60 1 TBA
2.5mm 200m 2 Cores & CPC VFP-225EWH200M 20 1 TBA
2.5mm 500m 2 Cores & CPC VFP-225EWH500M 10 1  TBA

White 4mm Cores & CPC (earth) Reel Cores Code Pallet Min Qty Trade Per 100m
4mm 100m 2 Cores & CPC

  VFP-S240EWH

60 1 TBA

back to top

NoBurn Platinum Standard Fire Performance Cable

    Black       Black Reel Cores Code Pallet Min Qty Trade Per 100m

1.5mm 100m 2 Cores & CPC VFP-215EBKH 60 1 TBA
2.5mm 100m 2 Cores & CPC VFP-225EBKH
      
60 1 TBA
1.5mm 100m 4 Cores & CPC VFP-415EBKH 60 1 TBA

*Cable prices will vary due to changes to copper costs*

back to top

Fire Performance Cable Part Code Break Down

VFP-210ER

VFP - 2 10 E R H  
Product Type   Conductors CSA CPC Type Outer Sheath Colour Core Colours Length
Ventcroft Fire Performance
Cable "NoBurn Platinum"

 

  2 - 2 Core

4 - 4 Core

10 - 1.0mm

15 - 1.5mm

25 - 2.5mm

E - CPC & Screen
 
R - Red

W - White

H- Harmonised Colours

- Old Colours

 

- 100M

50 - 50M

500 - 500M

750 - 750M

(M = Metre)

 

EC Declaration of Conformity
 

Full Part Code break down including Specials

Understanding the Standards and Tests

 

 Revised:08/01/2015

 
 
         